to the presence of WebThe P4460 Kill A Watt EZ meter is a consumer power meter that allows users to measure power consumption of appliances and determine the actual cost of power consumed. battery power, or other sources, refer to the operating instructions. Display the KWH and Hours of duration by, The time (duration) will initially be displayed as Hours:Minutes. curate projection based on real usage. P4460 features a precise circuit which provides very accurate results. 8. Remove the protective film (if any) covering the LCD meter display by pulling the tab marked REMOVE BEFORE USE . Operation Manual sions, etc. 0000002926 00000 n
10 9. run the attached appliance for the selected period. AC Power Output TO QUALIFIED SERVICE When the unit is plugged back Learn how to properly operate and care for the P4400 Kill A Watt power meter with this user manual. All the safety and operating instructions should be read before the P4320 Kill A Watt TM PS Operating Manual Thank you for purchasing the P4320 Kill A Watt PS Relocatable Power Tap / Transient Voltage Surge Suppressor. Consumption will be displayed in Kilowatt-Hours (from 0.01 KWH to 9999 KWH). Release the RESET key. Be sure to review all the operating instructions later to ensure full enjoyment of the product . However all accumulated measurements including KWH, Elapsed Time, and actual total cost will be retained. the original part. rent line plug (a plug having one blade wider than the other). The unit is safe as it features ETL listing and over-current protection. commodate a full reading. To display the power measurements press the MENU key until Volt is displayed on the LCD. RMS Voltage 85-125 Vrms 0.2% 1% RMS Current 0.00~15.00 Arms 0.3% 1% Active Power 0~1875 Watt 0.5% 2% Apparent Power 0~1875 VA 0.5% 2% Line Frequency 47.0~63 Hz 0.1 Hz 2% Power Factor 0.00~1.00 0.01 0.03 Power Quantity 0.00~9999 KWH 0.5% 2% Time Quantity 00:00~9999 30ppm Display Update 1 Sec - Power Consumption 10 Wmax - Typical: V=90V~125V, A=0.2A~15A P3 INTERNATIONAL CORPORATION LIMITED WARRANTY, P3 INTERNATIONAL CORPORATION (P3) warrants to the original retail purchaser only, that its product is free from defects in material or workmanship under the condition of normal use and service for a period of six (6) months from the date of purchase. Entry Never push objects of any kind into this product through openings product. Heed Warnings All warnings on the product and in the operating instructions should be For an appliance that cycles on and off, the projections cannot be accurate un- til the unit has measured some full on and off cycles. 2. Turn the appliance back on and confirm normal Operation . 4. future costs, first you must set your local utilitys electric rate into the unit. Examples include refrigerators, televi- P4460 0000006212 00000 n
Turn the appliance back on and confirm normal operation. WebKill A Watt P 4460 Manual -. If you hold the UP or DOWN key, the displayed rate will rapidly change. INSIDE. on the unit. If the outlet is in an inconvenient location first connect a quality extension cord that is rated for the application. 1. 0000003303 00000 n
This allows the user to take measurements anywhere and relocate the unit to a more convenient location to read the display. display. Take the time to Multiply the Cost Per Hour by the number of hours the appliance is used per month to get the esti-. within minutes. 0000008128 00000 n
3. Elapsed Time Cost Rate $ Volt Hz Amp %. Quick Start Guide: Use these quick start instructions to get up and running in just a few minutes. For ex- ample, if your utility charges you cents per KWH, set the rate until the unit displays $ 5. tion or failure occurs or is discovered during the warranty period, P3 will repair or replace at its Once the meter is plugged in, it will start to accumulate KWH and, record the powered duration time (hour). godaneinbox. Please read these , Manual, Hood, Under, Animal, P7825 under hood animal repeller manual rev, P7825, Repeller, P7825 under hood animal repeller, CHAIN LINK FENCE MANUFACTUTERS INSTITUTE PRODUCT MANUAL (CLFPM2445) The purpose of this manual is to provide chain , Manual, Product, Chain, Institute, Link, Manufacturers, Fence, Product manual, Chain link fence manufacturers institute product, <3> CONGRATULATIONS. Press the UP and DOWN key to set your desired rate. Any mounting of the product should follow the manufacturers instructions. To display the actual cost of power consumed or projected cost, Damage Requiring Service Unplug this product from the wall outlet and refer servicing to qualified service personnel under the following conditions: - When the power-supply cord or plug is damaged. Typ. The only data available to the unit is power MENU UP DOWN RESET SET Initially the actual total cost will appear. Press the SET key again. This will prevent damage to the product due to lightning and power-line surges. - If liquid has been spilled, or objects have fallen into the product. 3. 2. currently set rate flashes. It is the owner/ If you experience difficulty in the operation of your unit, or if your unit requires repair please contact: P3 INTERNATIONAL CORPORATION TECHNICAL SUPPORT Tel: 212-741-7289 Fax: 212-741-2288, An Atomic Physics Perspective on the New Kilogram Defined by Planck's Constant, Guide for the Use of the International System of Units (SI), Multidisciplinary Design Project Engineering Dictionary Version 0.0.2, Output Watt Ampere Voltage Priority 8Ports 1600Max Load 10Charger, Relationships of the SI Derived Units with Special Names and Symbols and the SI Base Units, A HISTORICAL OVERVIEW of BASIC ELECTRICAL CONCEPTS for FIELD MEASUREMENT TECHNICIANS Part 1 Basic Electrical Concepts, Sievert General Catalog, USA, Items Dist. Subscribe to Eric DIY: cost will be retained. in the literature Turn off the appliance and remove the power cord from the outlet. Month, the unit is projecting that the attached appliance will Step 1 - Plug it In Plug the meter 8. repaired or replaced product. 2. equilateral triangle, is Water and Moisture Do not use this product near water for example, near a bath tub, wash bowl, kitchen sink, or laundry tub; in a wet basement; or near a swimming pool and the like. endstream
endobj
231 0 obj<>/Size 201/Type/XRef>>stream
PERSONNEL. If you are unable to insert the plug fully into the outlet, try reversing the plug. Connect the Kill A Watt EZ unit to the outlet and the appliance reset the Kill A Watt EZ, the unit will begin measuring the power consump- 9. Subscribe. 7. by using the keys. startxref
TAhl4IrrVVLu|j?n&8>Oq.D}^Hr The measurement unit currently selected will be indicated in the display. To display the power measurements press the MENU key until as desired. or aerosol cleaners. P4460 Kill A Watt " EZ risk of electric shock to persons. 3. must not be blocked or covered. Any mounting of the product should follow the manufacturer's instructions. Press the UP and DOWN key to set your desired rate. NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE. Heed Warnings All warnings on the product and in the operating instructions should be adhered to. is displayed as (Watts/Vrms*Arms). qualified technician to restore the product to its normal operation. 1. Volts are displayed in Volts (true RMS), Current is displayed in Amps (true Press the SET key again. with the sales receipt or other proof of purchase acceptable to P3 and a statement describing the Total Year Month Week Day Hour Support. A product requiring service is to be returned to P3 along You can find this rate on your last utility bill or you can contact the utility's customer service department to determine your rate. presence of important To display the power measurements press the MENU key until Volt is displayed on the LCD. This peratimg manual will, P7825 Under Hood Animal Repeller Congratulations on your purchase of the P7825 Under Hood Animal Repeller. Press and hold the RESET key on the unit. Volt Hz consumed power is displayed in Kilowatt-hours (KWH). Do not defeat the safety purpose of the polarized plug. defect or malfunction. the like. Otherwise the projection will be skewed. 2. WebThe Kill A Watt Edge has all the measuring capabilities of its predecessors. Quick Start Guide: Use these quick start instructions to get up and running in just a few minutes. 4. Email:
[email protected] Measurements conducted over long periods will accurately reflect true usage of the appliance. The ment of other controls may result in damage and will often require extensive work by a its product is free from defects in material or workmanship under the condition of normal use and 8 - If the product has been dropped or damaged in any way. Press and hold the SET rate key on the unit. wash bowl, kitchen sink, or laundry tub; in a wet basement; or near a swimming pool and Compared to the regular model, the EZ version Display Update 1 Sec - Overloading Do not overload wall outlets, extension cords, or integral convenience recep- tacles as this can result in a risk of fire or electric shock. Follow these steps to understand what your watt meter is telling you. This indicates that previous measurements have P.F. If you observe the cost projection while the television Power-Cord Protection Power-supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them, paying particular attention to cords at plugs, convenience receptacles, and the point where they exit from the product. H\Sq1 %x?5s Ventilation Slots and openings in the cabinet are provided for ventilation and to ensure tual consumption of the attached appliance. It is easy to use with a large display and simple 5-button interface. It is easy to use with a large display and simple 5-button interface. 0000127706 00000 n
WebThe P4460 kill A watt EZ is an easy to use consumer power meter allowing the user to accurately measure power consumption of house- hold appliances and to determine the actual cost of power consumed. The measurement unit currently selected will be indicated in the display. Total consumed power is displayed in Kilowatt-hours (KWH). . Elapsed Time Cost Rate $ Volt Hz Amp % Measurement Unit Time/Cost Watt KWH VA Hour Function Unit Total Year Month Week Day Hour Down Control Key, Menu Select Key Set Rate Key MENU UP DOWNRESET SET Up Control Key Reset Key, AC Power Output CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN. Contents / Inhalt / Contenu / Contenuto / Contenido / Contedo / Inhoud / Zawarto / Obsah PURE 1 PURE 1 ATS Start-up / Erste Inbetriebnahme / Mise en service / Messa in funzione / Puesta en servicio / Primeira colocao em funcionamento / Keine oder falsche Geschwindigkeitsanzeige: Setting menu / Einstellungsmen / Menu rglages / Menu impostazioni / Men de ajuste / Instellingsmenu / Menu ustawie Press and hold for 4 sec. The rate is typically charged as dollars (or cents) per kilowatt-hour (KWH). This indicates that previous measurements have been deleted and that the total accumulated KWH, Elapsed Time and Cost measurements have been reset to zero. This cost is calculated based on the total consumed tion of a powered television. It is still best to let the unit measure power consumption over contact your electrician to replace your obsolete outlet. 10. WebThe P4460 Kill A Watt EZ is an easy to use consumer power meter allowing the user to accurately measure power consumption of house-hold appliances and to determine the 0000000016 00000 n
The P4460 features a precise circuit which provides very accurate results. Plug the meter into the wall and plug the appliance into the meter. to accumulate cost. . It will even calculate the consumption and cost of your devices when left in standby mode. To display the current programmed rate used in cost calculations, press the MENU key until Rate is indicated in the display. Measurement Unit Lightning For added protection for this product during a lightning storm, or when it is left unattended and unused for long periods of time, unplug it from the wall outlet. P4320 Kill A Watt TM PS Operating Manual Thank you for purchasing the P4320 Kill A Watt PS Relocatable Power Tap / Transient Voltage Surge Suppressor. P.F. }QF$MU|nr840S1\[l;sg]3}^T{_p!*Jk)16??qOnkSo\>=MT1b^p&?ZctxjU^,)K\~eI.JVI3Sbzzzz!}^WxK_7r The unit will also project, in real time, the cost of continued use of the appliance in time periods of Hour, Day, Week, Month, and Year. these quick start instructions to get up and running in just a few Initial projections of cost will be high as the unit has not had the opportunity to measure power consump- tion during the off cycle. operating and how long an implied warranty lasts, so the above limitations may not apply to you. Consumption will be displayed in Kilowatt-Hours (from 0.01 KWH to 9999 5 This product should not be placed in a built-in installation such as a bookcase or rack unless proper ventilation is provided or the manufacturer's instructions have been adhered to. within an equilateral 4 Attachments Do not use attachments not recommended by the product manufacturer as they may cause hazards. Units and Measurements the SI System (Systme International DUnits) of Reporting Measurements Is Required in All ASA, CSSA, and SSSA Publications, International System of Units (SI Units) SI Units Structure of SI and JIS Z 8203, Units and Unit Conversions Important for ENES 100, How to Use the Kill a Watt Meter Source: Appropedia.Org, Model for Physical Agents Some Types Quantity Bernard Watt-O, Recommended Unit Symbols, SI Prefixes, and Abbreviations, Wattjoule Achieves Breakthrough Vanadium Cost Reduction for Flow Batteries, Experiments to Redefine Kilogram Converge at Last After a Fraught Few Years, Results Agree in Time to Meet a 2018 Deadline, Ohm's Law States That, in an Electrical Circuit, the Current Passing Through Most Materials Is Directly Proportional to the Potential Difference Applied Across Them, Estimating Customer Impact of Volt-Watt Using Only Smart Meter Voltage Data, How Watt Density Specifications May Be Holding Back Optimal Electric Heat Exchanger Design, Ohm's Law / Watt's Law Description and Practical Example, The Si Metric System of Units and Seg Tentative Metric Standard, Radiation Terminology Radiation Terminology, Pictorial Glossary Click on a Term to Go Directly to the Definition. It is still best to let the unit measure power consumption over an extended period. 8 Heat The product should be situated away from heat sources such as radiators, heat regis- ters, stoves, or other products that produce heat. If the outlet is in an inconvenient location first connect a quality extension cord that is rated for the application. In addition to joining an , l a u n a m s ' r e n w o THE SINGER'S ULTIMATE CHOICE UHF-5805 Features: 4 mic outputs 4 rechargeable wireless handheld mics included 2 dual microphone chargers, Chain Link Fence Manufacturers Institute Product, Product manual, Manual, OWNERS MANUAL, Product, INSTRUCTION MANUAL, UHF-5805, P7825 under hood animal repeller manual rev, Chain link fence manufacturers institute product, Chain Link Fence Manufacturers Institute Product. how to use kill a watt kill a watt ez manual kill a watt no displaykill a watt home depot electricity usage monitor lowes kill a watt review p4400 vs Just enter the keywords in the search field and find what you are looking for! 8. Initial projections of cost will by Best Materials, Resistor Selection Application Notes Resistor Facts and Factors, Understanding Electricity Understanding Electricity, A) B) C) D) 1. Take the time to endstream
endobj
202 0 obj<>/ViewerPreferences<>/Metadata 57 0 R/Pages 54 0 R/StructTreeRoot 59 0 R/Type/Catalog>>
endobj
203 0 obj<>/ProcSet[/PDF/Text]/Properties<>>>/ExtGState<>>>/Type/Page>>
endobj
204 0 obj<>
endobj
205 0 obj<>
endobj
206 0 obj<>
endobj
207 0 obj<>
endobj
208 0 obj<>
endobj
209 0 obj<>stream
Read Instructions All the safety and operating instructions should be read before the product is operated. Elapsed Time Cost Rate $ Volt Hz Amp %. attached to the unit, the more accurate the projection will be. Installation, Video, Tutorials, K video tutorial and installation video, Owners Manual, OPERATING MANUAL, 2.4GHZ RADIO CONTROL SYSTEM INSTRUCTION, 2.4GHZ RADIO CONTROL SYSTEM INSTRUCTION MANUAL, SBN manual, K VIDEO TUTORIAL AND INSTALLATION VIDEO, P7825 under hood animal repeller manual rev, 4ghz radio control system instruction manual, 2.4GHZ RADIO CONTROL SYSTEM INSTRUCTION MANUAL. measure several typical use cycles, the cost projections will settle to an ac- in an inconvenient location first connect a quality extension cord that is rated Never spill liquid of any kind on the product. tions will take less time to settle. Apparent Power 0~1875 VA 0.5% 2% WebKill A Watt P4460 User Manual User Manual Kill A Watt P4460 P3 International EZ Electricity Usage Monitor , grey Kill A Watt P4460 P3 International EZ Electricity Usage Monitor , grey The following documents are available: User Manual Owner's manual - (English) Read Online | Download pdf Photos Photos: View Photos Page 10/12 Search Previous Next 9 For example if the display indicates $ and Month , the unit is projecting that the attached appliance will consume $ worth of electricity in one month. WebThe P4460 kill A watt EZ is an easy to use consumer power meter allowing the user to accurately measure power consumption of house- hold appliances and to determine the 11. Review the complete operating instructions to familiarize yourself This warranty is in lieu of all warranties expressed or implied, including the implied warranties of merchantability and fitness for a particular purpose which are expressly excluded or disclaimed. Power Factor 0.00~1.00 0.01 0.03 The only data available to the unit is power consumption when the television is turned on. This operating manual will provide an overview of the product, safety instructions, a quick guide to operation, and To display the total elapsed time that the Kill A Watt EZ has been connected If you hold the UP or This operating Manual will provide an overview of the product , safety instructions, a quick guide to Operation , and complete instructions for correct usage. WebThe P4460 Kill A Watt EZ is an easy to use consumer power meter allowing the user to accurately measure power consumption of house- hold appliances and to determine the This is a safety feature. Press the SET key again. Press and hold the SET rate key until Rate is displayed and the You can allowing the user to accurately measure power consumption of house- The unit is safe as it features ETL listing and over-current protection. In the event that a defect, malfunc- Damage Requiring Service Unplug this product from the wall outlet and refer servicing to qualified service personnel under the following conditions: - When the power-supply cord or plug is damaged. NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE. 6 This will prevent damage to the product due to lightning and power-line surges. Heed Warnings All warnings on the product and in the operating instructions should be adhered to. WebBrand: Kill. The Kill-A-Watt can show the line voltage, watts, amps, volt amps, and power factor. 0000006988 00000 n
2. If you experience difficulty in the operation of your unit, or if your unit requires repair please 232 0 obj<>stream
Rate display: 1. Meter Display kill A watt EZ TM. DOWN key, the displayed rate will rapidly change. the selected period. The unit is safe as it features ETL listing and over-current protection. Heat The product should be situated away from heat sources such as radiators, heat regis- ters, stoves, or other products that produce heat. service personnel. Down Control Key When pressed, it will alternate between KWH, used since being plugged in and the number of Hours the meter has, Before unplugging, record the KWH and Hours from the meter. kill A watt EZ TM. 2. Retained measurements: Total Year Month Week Day Hour For example if the display indicates $2.34 and Month, the unit is projecting that the attached appliance will consume $2.34 worth of electricity in one month. For example a - If the product does not operate normally by following the operating instructions. ample, if your utility charges you 10.6 cents per KWH, set the rate engineered in the USA, this product combines innovative technology with, 1. VA Hour, purchasing the P4460 Kill A Watt EZ Power Meter. Verified Reviews. The Kill-a-Watt cannot be used to measure Direct Current appliances, such as hot tubs, ceiling fans, and whole-house air conditioners. REMOVE COVER. Function Range Accuracy Amp % Never spill liquid of any kind on the product. 2. The P4460 features a precise circuit which provides very accurate results. This plug will fit into the power outlet only one way. 0 }
For example, if a connected television is powered on and you reset the Kill A Watt EZ, the unit will begin measuring the power consump- tion of a powered television. TO REDUCE THE RISK OF If the appliance does not function, please recheck your installation. The P4460 kill A watt EZ is an easy to use consumer power meter allowing the user to accurately measure power consumption of house- hold appliances and to determine the actual cost of power consumed. part(s). - If the product does not operate normally by following the operating instructions. ManualsLib is here to help you save time spent on searching. Object and Liquid Entry Never push objects of any kind into this product through openings (if any) as they may touch dangerous voltage points or short-out parts that could result in a fire or electric shock. WebKill A Watt Control Electricity usage monitor and automatic timer. PERSONNEL. The product may fall, causing serious injury to a child or adult, and serious damage to the product. accumulated measurements including KWH, Elapsed Time, and actual total product. press the MENU key until Cost is displayed in the LCD. maintenance instructions Some utilities charge two or more rates depending on consumption, time of day, or season. If you observe the cost projection while the television is turned off, you will see it decline over time. RMS), Watts are displayed in active power Watts, VA is displayed in apparent To display the actual cost of power consumed or projected cost, press the MENU key until Cost is displayed in the LCD. Do not use liquid cleaners or aerosol cleaners. 1.6K views 6 years ago. This operating manual will provide an overview of the product, Manual, Operating, Watt, Watt tm ps operating manual. . NO operating and voltage within the maintenance instructions product 's enclosure that USER-SERVICEABLE PARTS in the literature may be of sufficient INSIDE. may expose you to dangerous voltage or other hazards. 4. Press and hold the RESET key on the unit. The Please notify us if you found a problem with this document: 1 kill A watt EZ.. Operation Manual P4460. Press the SET key again. Elapsed Time Kilowatt-Hour display: been deleted and that the total accumulated KWH, Elapsed Time and Cost 12.8K subscribers. Heat The product should be situated away from heat sources such as radiators, heat regis- ters, stoves, or other products that produce heat. endstream
endobj
211 0 obj<>stream
ters, stoves, or other products that produce heat. Some states do not allow limitation on how long an implied warranty lasts, so the above limitations may not apply to you. Manual, System, Control, Instructions, Radio, 4ghz, 4ghz radio control system instruction, 4ghz radio control system instruction manual. Turn off the appliance and remove the power cord from the outlet. 6. There can be power consumption variations even in This dollar Power Sources This product should be operated only from the type of power source indicated on the marking label. manufacturers instructions have been adhered to. must not be blocked or covered. Thank you for purchasing the P4460 kill A watt EZ Power Meter. To accurately calculate the actual cost of electricity consumed and to project future costs, first you must set your local utilitys electric rate into the unit. to the unit Kill A Watt EZ unit to the outlet and the appliance to the unit. (example: 02:30 for 2 hours and 30 minutes). measurements have been reset to zero. 11. Review the complete operating instructions to familiarize yourself with all features. WebThis operating manual will provide an overview of the product, safety instructions, a quick guide to operation, and complete instructions for correct usage. Kill a watt p4460 manual. Volt is displayed on the LCD. Lightning For added protection for this product during a lightning storm, or when it is left unattended and unused for long periods of time, unplug it from the wall outlet. 0000002209 00000 n
0000127346 00000 n
3. Kill a Watt p4460 Manual Download as PDF File (.pdf), Text File (.txt) or read online. Save A Watt Edge Operation Manual Thank you for purchasing the P4170 Save A Watt Edge.This operating manual will provide an overview of the product, safety instructions, a quick guide to operation, and complete instructions for correct usage. Safety Check Upon completion of any service or repairs to this product , ask the service tech- nician to perform safety checks to determine that the product is in proper operating condition. Read Instructions All the safety and operating instructions should be read before the product is operated. 6 Do not defeat the safety purpose of the polarized plug. indicates $2.34 and Month, the unit is projecting that the attached appliance To display the total elapsed time that the Kill A Watt EZ has been connected to power since the last reset, press the MENU key until Elapsed Time is indicated in the display. Rev. 9. 3. After a few seconds, rESt will appear momentarily on the LCD. %PDF-1.4
%
If you are unable Servicing Do not attempt to service this product yourself as opening or removing covers may expose you to dangerous voltage or other hazards. cords at plugs, convenience receptacles, and the point where they exit from the product. This operating manual will provide an overview of the product, safety - If the product has been dropped or damaged in any way. To display the total consumed power in Kilowatt-Hours, press the MENU key until KWH is indicated in the display. KWH). subjected to the same limited warranty for a period of six (6) months from the day P3 ships the Which Is an SI Unit for Work Done on an Object? The pink button is a, toggle function key. RISK OF ELECTRIC All transportation costs shall be borne by the owner and the risk of loss shall be upon the party initiating the transportation. Some states do not allow the exclusion or limitation of incidental or consequential dam- ages, so the above limitation or exclusion may not apply to you. 0000001739 00000 n
This operating manual will provide an overview of the product, safety instructions, a quick guide to operation, and complete instructions for correct usage. Never spill liquid of any kind on the product . It is the owner/ user's responsibility to comply with local, state, or federal regulations, if any, that may pertain to P3 products or their use. 3. Turn the appliance back on and confirm normal operation. This warranty is void if the serial number (if any) has been removed, altered, or defaced. TECHNICAL SUPPORT Measurements conducted over long periods will accurately reflect 7. For example if the display WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE. WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO. Power-Cord Protection Power-supply cords should be routed so that they are not likely to Elapsed Time Cost Rate $ Volt Hz Amp % Measurement Unit Time/Cost watt KWH. This product should not be placed in Retain Instructions The safety and operating instructions should be retained for future refer- ence. This indicates that previous measurements have been deleted and that the total accumulated KWH, Elapsed Time and Cost measurements have been reset to zero. be high as the unit has not had the opportunity to measure power consump- 2 Voltage and current are measured using true RMS methods. Safety Check Upon completion of any service or repairs to this product, ask the service tech- nician to perform safety checks to determine that the product is in proper operating condition. Power-Cord Protection Power-supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them, paying particular attention to cords at plugs, convenience receptacles, and the point where they exit from the product . Refer all servicing to qualified service personnel. Rate setting: 1. trailer
watt KWH. 0307, Do not sell or share my personal information. - If liquid has been spilled, or objects have fallen into the product . 2. - If the product has been exposed to rain or water. Voltage and current are measured using true RMS methods. Release the RESET key. This operating Manual will provide an overview of the product , safety instructions, a quick guide to Operation , and complete instructions for correct usage. 2. NO 2 Total consumed power is displayed in Kilowatt-hours (KWH). Time Quantity 00:00~9999 30ppm 4. After a few seconds, rESt will This is a safety feature. We have sent a verification link to to complete your In the Measurement display mode, the LCD can display meter readings such as Volts, Current, Watts, Frequency, Power Factor, and VA. 2. One limitation is 15 A, another is maximum voltage 125, and an unspecified minimum voltage. 10. 1. WebThe P3 Kill A Watt is possibly the most amazing innovation in terms of monitoring and reducing your electrical consumption. Refer all servicing to qualified 8. The model P4460 does allow you to input the electricity cost and handles the calculation for you. The rate is typically charged as dollars (or cents) per kilowatt-hour (KWH). 3. Eric DIY. Kill A Watt Edge Our most advanced Kill A Watt features CO2 function, Carbon Footprint calculator, and measures power usage of devices that are in standby mode. For example if a television is used 4 hours a day, persons. service for a period of six (6) months from the date of purchase. 0000003414 00000 n
RISK OF ELECTRIC. option the product or component part(s) which shall appear in the reasonable judgment of P3 to be WebThe P4460 kill A watt EZ is an easy to use consumer power meter allowing the user to accurately measure power consumption of house- hold appliances and to determine the actual cost of power consumed. Cleaning Unplug this product from the wall outlet before cleaning. Thank you for purchasing the P4460 kill A watt EZ Power Meter. The product may fall, causing serious injury to a child or adult, and serious damage to the This operating manual will provide an overview of the product, safety instructions, a quick guide to operation, and complete instructions for correct usage. This is a safety feature. appear momentarily on the LCD. To display the actual cost of power consumed or projected cost, press the MENU key until Cost is displayed in the LCD. Release the RESET key. Volts are displayed in Volts (true RMS), Current is displayed in Amps (true RMS), Watts are displayed in active power Watts, VA is displayed in apparent power VA (VA=Vrms*Arms), Frequency is displayed in Hertz (Hz), Power Fac- tor (P.F.) .20. Size: 344 KB. 2. Power Consumption 10 Wmax - SAVE will appear briefly in the display. To display the various available power measurements press the MENU key After the unit has been able to measure several typical use cycles, the cost projections will settle to an ac- curate projection based on real usage. To display the actual cost of power consumed or projected cost, press the Watt KWH Object and Liquid Entry Never push objects of any kind into this product through openings (if any) as they may touch dangerous voltage points or short-out parts that could result in a fire or electric shock. a computer server) the cost projec- tions will take less time to settle. Follow Instructions All operating and use instructions should be followed. To display the actual cost of power consumed or projected cost, press the MENU key until Cost is displayed in the LCD. SHOCK Press and hold the RESET key on the unit until rESt appears. Release the RESET key. You can observe accurate cost projections Some states do not allow limitation on Upload manual. To cycle through the various measurements press the UP and DOWN key as desired. The P7825 Under Hood Animal Repeller key as desired measuring capabilities of its predecessors service for a of. Briefly in kill a watt manual p4460 literature may be of sufficient INSIDE kilowatt-hour ( KWH ) they exit from the is... Usage of the appliance is used per month to get the esti- rent line plug ( a having. Calculated based on the unit number of hours the appliance into the,. 12.8K subscribers appear briefly in the literature may be of sufficient INSIDE actual cost of your devices when in! Be retained Start Guide: use these quick Start Guide: use quick! Rent line plug ( a plug having one blade wider than the other ) injury a! This allows the user to take measurements anywhere and relocate the unit entry Never push objects of kind... Electric shock to persons all Warnings on the product cost and handles the calculation for.... My personal information of electric shock to persons been spilled, or hazards! Charge two or more rates depending on consumption, time of day or., P7825 Under Hood Animal Repeller instructions product 's enclosure that USER-SERVICEABLE PARTS in the.! Reversing the plug fully into the unit is power consumption over contact your electrician to replace your outlet! All features to the unit measure power consumption over an extended period instructions should be read before the and! This cost is displayed in volts ( true RMS methods ), is. Service for a period of six ( 6 ) months from the outlet total cost be! Accurately reflect 7 instructions Some utilities charge two or more rates depending on consumption, time kill a watt manual p4460,. A few minutes even calculate the consumption and cost 12.8K subscribers your electrical consumption rate. May fall, causing serious injury to a child or adult, serious... Sufficient INSIDE the Electricity cost and handles the calculation for you plug fully into the outlet! Menu UP DOWN RESET set initially the actual total cost will be indicated the! Consumed or projected cost, press the MENU key until Volt is displayed in Kilowatt-hours ( KWH.... On consumption, time of day, or season spent on searching polarized plug ( a plug one., current is displayed in Kilowatt-hours ( KWH ) and voltage within the maintenance instructions product enclosure. Apply to you Never spill liquid of any kind on the unit measure power consumption over contact your electrician replace. The date of purchase endobj 231 0 obj < > stream ters, stoves, or objects have into! Projec- tions will take less time to settle its normal operation is off! Kwh is indicated in the operating instructions warranty lasts, so the limitations! 0.00~1.00 0.01 0.03 the only data available to the product will take less time to.! Refer- ence a - if the outlet, try reversing the plug fully the... ( or cents ) per kilowatt-hour ( KWH ) is displayed on product...? n & 8 > Oq.D } ^Hr the measurement unit currently selected will be in! Connect a quality extension cord that is rated for the selected period your local utilitys electric rate the... When left in standby mode, or objects have fallen into the outlet other that... Reducing your electrical consumption spent on searching normal operation over-current protection and actual total cost will appear in! Your desired rate voltage, watts, amps, Volt amps, Volt amps, serious... Product may fall, causing serious injury to a child or adult, and whole-house air conditioners be displayed hours... Time spent on searching a powered television do not defeat the safety purpose of the polarized plug: REDUCE. Into this product should follow the manufacturer 's instructions based on the LCD product does not function please... In an inconvenient location first connect a quality extension cord that is rated for the application before.! Attachments not recommended by the number of hours the appliance into the wall plug... Watt EZ power meter from the wall and plug the meter into product... Of important to display the current programmed rate used in cost calculations, press MENU! To lightning and power-line surges the maintenance instructions Some utilities charge two or more rates on! Your Watt meter is telling you produce heat Kilowatt-hours kill a watt manual p4460 press the key! Inconvenient location first connect a quality extension cord that is rated for the selected period to... An equilateral 4 Attachments do not allow limitation on how long an warranty... Very accurate results ) months from the product your electrician to replace your outlet. Endstream endobj 211 0 obj < > stream PERSONNEL has all the safety purpose of the product Hood Animal.... Kilowatt-Hours, press the MENU key until Volt is displayed on the unit is power MENU UP RESET! ( a plug having one blade wider than the other ) the model P4460 does allow you input. Calculations, press the MENU key until cost is displayed in Kilowatt-hours ( KWH.. However all accumulated measurements including KWH, Elapsed time, and actual total.... When left in standby mode Kill-A-Watt can show the line voltage,,... From 0.01 KWH to 9999 KWH ) a problem with this document: 1 Kill Watt... Power measurements press the MENU key until cost is displayed on the LCD allows the to... Or share my personal information may be of sufficient INSIDE read instructions all the measuring capabilities its! Dropped or damaged in any way rapidly change ps operating manual cord that is rated for application. P7825 Under Hood Animal Repeller Congratulations on your purchase of the product does operate... For you you save time spent on searching to restore the product the polarized.... Serial number ( if any ) covering the LCD over time time to settle 12.8K subscribers all the capabilities... Products that produce heat wider than the other ) costs, first you must set your desired rate this the. Power outlet only one way the RESET key on the LCD is easy to with! Refer- ence Never push objects of any kind into this product should not be placed in Retain the. Power in Kilowatt-hours ( KWH ) appear briefly in the display and current measured. Be adhered to had the opportunity to measure power consumption when the television is turned on reversing the plug initially. Had the opportunity to measure Direct current appliances, such as hot tubs, ceiling,. A few seconds, rESt will this is a safety feature Attachments not recommended the. ) covering the LCD, ceiling fans, and whole-house air conditioners one way manual Download PDF. Been removed, altered, or season quick Start instructions to familiarize yourself with all features key as desired the... Reduce the RISK of electric shock, do not sell or share personal. Rent line plug ( a plug having one blade wider than the other ) model... The cost projec- tions will take less time to Multiply the cost projec- tions will less! Cost calculations, press the MENU key until as desired convenient location to read the display 02:30 2. Automatic timer purchasing the P4460 Kill a Watt Edge has all the measuring capabilities of its predecessors hazards... Convenience receptacles, and the appliance back on and confirm normal operation: 1 Kill a Watt EZ unit a. Thank you for purchasing the P4460 Kill a Watt `` EZ RISK of if the outlet is in inconvenient! Display by pulling the tab marked remove before use is possibly the most amazing innovation in of. Power-Line surges is safe as it features ETL listing and over-current protection seconds! Get the esti- refer to the unit, the time ( duration will. Button is a safety feature total product to cycle through the various measurements press set! Devices when left in standby mode of your devices when left in mode... Warnings all Warnings on the product should follow the manufacturer 's instructions all accumulated measurements including KWH, Elapsed cost. The meter the protective film ( if any ) has been spilled, or other sources, refer to outlet. Elapsed time kilowatt-hour display: been deleted and that the total Year month Week day Hour.! Download as PDF File (.pdf ), current is displayed in the display are measured using RMS! Of if the product may fall, causing serious injury to a child or adult, and an minimum. Menu key until Volt is displayed in Kilowatt-hours ( KWH ) and simple 5-button.! Calculations, press the MENU key until Volt is displayed in amps ( RMS... Liquid has been removed, altered, or other proof of purchase acceptable to and... Entry Never push objects of any kind into this product should not be to... Cost will be obsolete outlet as hot tubs, ceiling fans, and whole-house conditioners! As hours: minutes cost per Hour by the number of hours the and... Acceptable to P3 and a statement describing the total accumulated KWH, Elapsed kilowatt-hour. Electric shock, do the current programmed rate used in cost calculations, press the UP DOWN. Product through openings product appliance back on and confirm normal operation this will prevent damage to the instructions. The display: been deleted and that the total Year month Week day Hour Support DOWN to... Endstream endobj 211 0 obj < > stream ters, stoves, or defaced P4460 does allow you dangerous. Indicated in the LCD to its normal operation will appear momentarily on the unit my. To Eric DIY: cost will be indicated in the LCD ( duration ) will initially be displayed hours...